PureStyle Release Notes ----------------------------- Version 32 05-May-2023 ============================= DEFECTS RESOLVED ---------------- 1) Resolved issue where an RGBA fixture would go full on when given an input intensity of 1/65535 and the fixture is configured with the Linear curve and an input mode of 3-to-4 with Chromasync. NEW FEATURES ------------ 1) Improved Chromasync performance. 2) Added support for improved low level dimming performance. KNOWN DEFECTS ---------------- None Version 26 10-January-2017 ============================= DEFECTS RESOLVED ---------------- 1) Resolved issue where the fixture will lock up if it receives data packets containing non-expectant start codes along with legitimate data packets. This issue was seen in certain environments with an Ethernet configured system. 2) Resolved issue where the fixture will lock up if the version string is written to. This will only be seen by development. 3) Resolved issue where false positive Posipower hardware events can occur when fixture parameter settings are read back and the fixture is configured with Livescan disabled. 4) Resolved issue where the fixture will flicker when given an input intensity below 255/65535 and the fixture is configured with the Tungsten curve and an input mode of 3-to-4 with Chromasync. 5) Resolved issue where fixtures dip in intensity around the green color during a ColorWash show and the fixture is sufficiently warm and configured with an input mode of 3-to-4 with Chromasync. 6) Resolved issue where LED strings will remain full on at certain input channel map settings. This setting is performed during manufacturing. NEW FEATURES ------------ 1) Fixture will now behave correctly if a non-standard LED Chemistry is selected during manufacturing. 2) Changes made to correct enter/exit critical code. KNOWN DEFECTS ---------------- None Version 20 07-October-2015 ============================= 1) Initial release. KNOWN DEFECTS ---------------- None